Olympus IPLEX GX Videoprobe –  4mm / 3.5m

Available as:
  • Rental

Olympus IPLEX GX Videoprobe –  4mm / 3.5m –  Available for rental/hire from Ashtead Technology.

With innovative image processing software and stereo measurement capabilities the Olympus IPLEX GX Videoprobe is suitable for inspection diameters from 4mm and comes with a 3.5m probe length.  

The Olympus IPLEX GX provides an exceptional view of your inspection area by combining a high-resolution CCD, an intensely-bright laser diode illumination system and PulsarPic image processing software.

To further enhance your visual inspection and the possibility of detecting defects, the IPLEX GX utilises a built-in 8 inch screen which allows you to perform live analysis on your application area. The NX can also record JPEG images and MPEG-4 videos, for further offsite analysis / reporting. 

Capable of stereo measurement inspection, the IPLEX NX can analyse the following defect characteristics -

  • Length/Distance
  • Depth
  • Point to Line
  • Area
  • Multi-Segment Length

Key features

  • Scope diameter: 4mm
  • Length: 3.5m
  • Stereo measurement: Yes
  • Image Software: PulsarPic + InHelp
  • Light Source: Built-in Laser Diode Illumination
  • Output: Image / Video
  • Tip Articulation: Up/Down, Left/Right (up to 130°)
  • Power: 150 Minute Battery Pack x 2, Mains Lead and Battery Charger

Applications

  • Aerospace
  • Oil & Gas
  • Power Generation
  • Wind Power
  • Process Industries

Technical specifications

Software options
Image features5X digital zoom, 16-step brightness control
Gain control4-step adjustable gain control (Manual, Auto, Wider1, Wider2)
Dynamic noise reductionAvailable
Sharpness control4-step adjustable sharpness control
Saturation control3-mode adjustable control of colour saturation (Monotone, Natural, Vivid)
Display text options30-character title display
Note text options30-character title display, mark, free drawing
Image display functionsLive image can be inverted to right and left, inverted to up and down, and rotated 180 degrees
Recording management functions
Recording media - NormalSDHC (with supplied SDHC)
Recording media - Constant VideomicroSDHC (using the recommended parts; set the constant video function to ON)
Internal MemoryAvailable (only the still images are recorded)
OverlayZoom, Brightness, Date/Time, Title, Optical Tip Adaptor, OLYMPUS logo, and system setting
Thumbnail image displayRecorded images can be displayed as thumbnails
Still image recording - ResolutionH768 x V576(Pixel)
Still image recording - Recording formatCompressed JPEG format
Video recording - ResolutionH768 x V576(Pixel)
Video recording - Recording formatMPEG 4 AVC/H.264 Conforms to baseline profile; Windows Media Player 12 compatible
Video recording - Frame rate60 fps / 30 fps
Measurement functions
Scalar measurementScalar measurement
Stereo Measurement functions
DistanceDistance between two points *1
Point-to-linePerpendicular distance between a point and a user-defined line *1
DepthOrthogonal depth/height distance between a point and a user-defined plane *1
Area/LinesMultiple point circumference and area measurement *1
Operating Environment
Operating temperature - Insertion tubeIn air: -25 ℃ to 100 ℃ (-13 °F to 212 °F); in water: 10 ℃ to 30 ℃ (50 °F to 86 °F)
Operating temperature - Other partsIn air: -10 ℃ to 40 ℃ (14 °F to 104 °F) (with battery) In air: 0 ℃ to 40 ℃ (32 °F to 104 °F) (with AC power adaptor and battery charge)
Relative humidity15 to 90%
Liquid resistanceOperable when exposed to machine oil, light oil, or 5% saline solution
Dust proofing and water proofing - Insertion tubeOperable under water with viewing tip adaptor attached Not operable under water with stereo measurement tip adaptors IV94 series - up to an equivalent to 3.5 m (11.5 ft) in depth IV96 series - up to an equivalent to 10 m (32.9 ft) in depth
Dust proofing and water proofing - Other partsIP65; not operable under water (battery cover and others must be closed)
MIL-STD Compliance
VibrationMIL-STD-810G, METHOD 514.7, Procedure I (general vibration test)
ShockMIL-STD-810G, METHOD 516.7 Procedure IV (transit drop test)
Water ResistanceMIL-STD-810G, METHOD 506.6, Procedure I (rain and blowing rain test)
HumidityMIL-STD-810G, METHOD 507.6, Procedure II (aggravated cycle)
Salt FogMIL-STD-810G, METHOD 509.6
Sand and DustMIL-STD-810G, METHOD 510.6, Procedure I (blowing dust test)
Icing/Freezing RainMIL-STD-810G, METHOD 521.4
Explosive AtmosphereMIL-STD-810G, METHOD 511.6, Procedure I (operation in an explosive atmosphere test)
Electromagnetic Interference (EMI)MIL-STD-461G, RS103 above decks
Scope unit
Model No.IV9435G
Insertion tube - Scope diameterΦ4.0 mm
Insertion tube - Scope length3.5 m (11.5 ft.)
Insertion tube - ExteriorHigh durability tungsten braid
Insertion tube - Tube flexibilityUniform stiffness
Insertion tube - Temperature sensor2-stage indicator for high temperature warning
Articulation Section - Articulation angle up/down/right/left130°
Articulation Section - Articulation operationTrueFeel electronic scope tip articulation / fine mode articulation control using the touch screen menu
IlluminationLED illumination
Base Unit
Model No.IPLEX GX
Display8-inch daylight view WVGA LCD with capacity-type touch screen, 5 step adjustable LCD backlight
Power supply - AC power100 V to 240 V, 50/60 Hz (with supplied AC adaptor)
Power supply - Battery10.8 V nominal, approx.(with supplied battery) Battery operation time: approx. 150 minute
Video output standard - HDMIType A HDMI 1.4
Headset (microphone in/ audio out)Φ3.5 mm mini plug CTIA  
Live image streamingAttach the recommended USB wireless LAN adapter to the Type A USB connector
Optical tips
AT100S/FF-IV94G
Optical system - Field of view100°
Optical system - Direction of viewSide
Optical system - Depth of field8 to ∞ mm
Distal end - Outer diameterΦ4.0 mm
Distal end - Distal end21.7 mm
IV94G-AT100S/NF
Optical system - Field of view100°
Optical system - Direction of viewSide
Optical system - Outer diameter2 to 15 mm
Optical system - Depth of fieldΦ4.0 mm
Distal end - Distal end21.7 mm
IV94G-AT120D/NF
Optical system - Field of view120°
Optical system - Direction of viewForward
Optical system - Depth of field2 to 200 mm
Distal end - Outer diameterΦ4.0 mm
Distal end - Distal end19.0 mm
IV94G-AT-120D/FF
Optical system - Field of view120°
Optical system - Direction of viewForward
Optical system - Depth of field17 to ∞ mm
Distal end - Outer diameterΦ4.0 mm
Distal end - Distal end19.0 mm
Stereo Tip Adaptors
AT50D/50D-IV94
Optical system - Field of view50°/50°
Optical system - Direction of viewForward
Optical system - Depth of field5 to ∞ mm
Distal end - Outer diameterΦ4.0 mm
Distal end - Distal end24.3 mm
AT50S/50S-IV94
Optical system - Field of view50°/50°
Optical system - Direction of viewSide
Optical system - Depth of field4 to ∞ mm
Distal end - Outer diameterΦ4.0 mm
Distal end - Distal end28.4 mm

Dimensions

Descriptionmminchkglbs
IPLEX GX - Base241 mm × 190 mm × 70 mm9.5 in. × 7.5 in. × 2.8 in1.77 kg
IPLEX GX - Scope97 mm × 188 mm × 158 mm 3.8 in. × 7.4 in. × 6.2 in.1.05 kg

Downloads